UOP 963 PDF
Original price was: $287.00.$172.00Current price is: $172.00.
Trace Aromatic Hydrocarbons in 90 to 400 degrees C Boiling Range Petroleum Distillates by HPLC
Published by | Publication Date | Number of Pages |
UOP | 01/01/1998 | 13 |
UOP 963 – Trace Aromatic Hydrocarbons in 90 to 400 degrees C Boiling Range Petroleum Distillates by HPLC
This method is for determining aromatics in petroleum distillates boiling in the range of 90 to 400 degrees C by High Performance Liquid Chromatography (HPLC). The method determines aromatics from 0.001 to 4 mass. Above 4 mass, use IP Method 391. The aromatics should be predominantly mono-substituted, single-ring aromatics. Multiple-ring aromatic compounds and aromatic compounds containing two or more alkyl-substituents bias the results high. Significant levels of benzene bias the results low. Compounds containing sulfur, nitrogen, and oxygen may interfere. Mono-alkenes do not interfere, but conjugated di-alkenes and polyalkenes may interfere.
Product Details
- Published:
- 01/01/1998
- Number of Pages:
- 13
- File Size:
- 1 file , 69 KB