SSPC PA 2 PDF

$20.00

Procedure for Determining Conformance to Dry Coating Thickness Requirements
standard by Society for Protective Coatings, 01/26/2015

PDF FormatPDF FormatMulti-User-AccessMulti-User AccessPrintablePrintableOnline downloadOnline Download
Category:

Description

This standard describes a procedure for determining shop or field conformance to a specified coating dry film thickness (DFT) range on ferrous and non-ferrous metal substrates using nondestructive coating thickness gages (magnetic and electronic) described in ASTM D 7091.

The procedures for adjustment and measurement acquisition for two types of gages: “magnetic pull-off” (Type 1) and “electronic” (Type 2) are described in ASTM D 7091.

This standard defines a procedure to determine whether dry coatings conform to the minimum and the maximum thickness specified. See Note 11.1 for an example of a possible modification when measuring dry film thickness on overcoated surfaces.

This document is not intended to prescribe a frequency of coating thickness measurement for a coating failure investigation.

Product Details

Published:
01/26/2015
Number of Pages:
13
File Size:
1 file , 560 KB
Note:
This product is unavailable in Ukraine, Belarus, Russia