IEC 62132-4 Ed. 1.0 b – Integrated circuits – Measurement of electromagnetic immunity 150 kHz to 1 GHz – Part 4: Direct RF power injection method
Describes a method to measure the immunity of integrated circuits (IC) in the presence of conducted RF disturbances, e.g. resulting from radiated RF disturbances. This method guarantees a high degree of repeatability and correlation of immunity measurements. This standard establishes a common base for the evaluation of semiconductor devices used in equipment functioning in an environment subject to unwanted radio frequency electromagnetic waves.