IEC 60332-3-23 Ed. 1.0 b PDF
Original price was: $61.00.$37.00Current price is: $37.00.
Tests on electric cables under fire conditions – Part 3-23: Test for vertical flame spread of vertically-mounted bunched wires or cables – Category B
Published by | Publication Date | Number of Pages |
IEC | 10/09/2000 | 25 |
IEC 60332-3-23 Ed. 1.0 b – Tests on electric cables under fire conditions – Part 3-23: Test for vertical flame spread of vertically-mounted bunched wires or cables – Category B
Specifies method of test for the assessment of vertical flame spread of vertically-mounted bunched wires or cables, electrical or optical, under defined conditions. The test is intended for type approval testing. The requirements for the selection of cables for testing are given. The flame spread is measured as the extent of damage of the cable sample. This procedure may be used to demonstrate the cable’s ability to limit flame spread. Covers category B and relates to cables installed on the test ladder to achieve a nominal total volume of non-metallic material of 3,5 l/m of test sample. The flame application time is 40 min. The method of mounting uses the front of the standard ladder. The category is intended for general use where medium volumes of non-metallic material are required to be evaluated. A recommended performance requirement is also given. Has the status of a group safety publication in accordance with IEC Guide 104.
Product Details
- Edition:
- 1.0
- Published:
- 10/09/2000
- Number of Pages:
- 25
- File Size:
- 1 file , 260 KB
- Note:
- This product is unavailable in Ukraine, Russia, Belarus